Published Last updated
- Affects
- Vendors and accredited labs testing physical cryptographic modules at security levels 3 or 4.
- Announcement date
- Nov 20, 2026
- Guidance effective date
- Nov 20, 2026
The CMVP’s November 20 update adds implementation guidance 7.4.A, effective that day, for environmental testing of FIPS 140-3 physical security levels 3 and 4. At level 3, a module may use environmental failure protection (EFP) or environmental failure testing (EFT); level 4 requires EFP. The full guidance specifies separate high and low temperature and voltage tests, documentation for the selected approach, and evidence that EFP shuts a module down or immediately zeroizes unprotected sensitive security parameters beyond operating limits. Vendors and accredited labs preparing affected physical module submissions should review their test plans and calibration evidence. Suggested action: Match the claimed level and module design to IG 7.4.A before filing. This is not a new test requirement for software-only modules. Related: FIPS 140-3 guidance and the SP 800-90C transition.
Suggested action: Compare physical module test plans and evidence with IG 7.4.A.