Enterprise technology / policy / securityClarity for IT decisions
IT Alerter
IT Notices / Security baseline

FIPS 140-3 adds environmental testing guidance for levels 3 and 4

Published Last updated

Affects
Vendors and accredited labs testing physical cryptographic modules at security levels 3 or 4.
Announcement date
Nov 20, 2026
Guidance effective date
Nov 20, 2026

The CMVP’s November 20 update adds implementation guidance 7.4.A, effective that day, for environmental testing of FIPS 140-3 physical security levels 3 and 4. At level 3, a module may use environmental failure protection (EFP) or environmental failure testing (EFT); level 4 requires EFP. The full guidance specifies separate high and low temperature and voltage tests, documentation for the selected approach, and evidence that EFP shuts a module down or immediately zeroizes unprotected sensitive security parameters beyond operating limits. Vendors and accredited labs preparing affected physical module submissions should review their test plans and calibration evidence. Suggested action: Match the claimed level and module design to IG 7.4.A before filing. This is not a new test requirement for software-only modules. Related: FIPS 140-3 guidance and the SP 800-90C transition.

Suggested action: Compare physical module test plans and evidence with IG 7.4.A.