Published Last updated
NIST and the Canadian Centre for Cyber Security updated the FIPS 140-3 Implementation Guidance on November 20, 2026. Three new sections address random bit generator validation, use of those generators in cryptographic modules, and environmental testing. A same-day version 2.8 of the CMVP Management Manual adds a minor administrative correction route and adjusts several validation procedures. The changes chiefly affect cryptographic module vendors and accredited Cryptographic and Security Testing Laboratories (CSTLs) preparing or reviewing FIPS 140-3 submissions. They do not announce a blanket replacement date for deployed products. The CMVP change summary and the management manual listing identify both current editions.
What the random bit generator guidance covers
NIST SP 800-90C specifies constructions for random bit generators (RBGs) that combine deterministic random bit generator mechanisms from SP 800-90A with entropy sources described in SP 800-90B. The November guidance gives those constructions a more explicit route through the Cryptographic Module Validation Program (CMVP). The new section D.T interprets SP 800-90C within the RBG validation itself; D.U covers what a FIPS 140-3 module must show when it uses or references an RBG. Keeping these two validation layers separate matters because an RBG certificate does not, by itself, establish that every surrounding module behavior meets FIPS 140-3.
D.T applies at all security levels and took effect November 20. It clarifies allowed deterministic generator choices, entropy-source handling, RBG health tests, and evidence needed for RBG validation. For example, its DRBG.1 resolution excludes SHA-1, SHA2-224, SHA2-512/224 and SHA3-224 from Hash_DRBG and HMAC_DRBG use within an RBG construction. Its entropy guidance addresses sources validated on only some operating environments: the RBG report must identify each source’s validation status by platform and explain how credited sources are selected. These are validation-specific conditions, not a claim that a particular commercial product is affected. The precise resolutions appear in IG D.T in the current implementation guidance.
D.U also took effect November 20 and applies at all security levels. It calls for a separate RBG Summary Template in the CMVP submission package, showing how each of its applicable “shall” requirements is met. A laboratory must map the module’s operating environment to the RBG and entropy-source operating environments when their certificates do not list identical environments. It must also test module obligations that an RBG validation may not cover, including sensitive security parameter handling and relevant error states for components inside the module boundary. The new guidance distinguishes an entropy-source health-test failure that SP 800-90C permits an RBG to survive from failures that require the module to enter an error state. See IG D.U requirements and examples.
The May 20, 2028 transition applies to new submissions
The most consequential date is in D.U’s TRNS.1. Eighteen months after this guidance’s November 20, 2026 publication, the CMVP says it will stop accepting new module submissions that directly reference entropy source validation “E” certificates. After that transition, those submissions must reference random bit generator “G” certificates and meet applicable SP 800-90C, D.T and D.U requirements. D.U labels the transition end as May 20, 2028. Its footnote defines “new submissions” as submission types required to meet the latest guidance at filing, giving full submissions and updates as examples and directing readers to the manual’s scenario table. This is a CMVP submission rule, not an end-of-support date for all modules already deployed.
The transition may be straightforward for an architecture that fits an existing RBG2 construction, but D.U cautions that some designs may need software, firmware or hardware changes. It specifically mentions the RBG2 reseed interval as an example, while noting that D.T relaxes part of that requirement. A vendor or CSTL should identify the actual RBG construction, entropy source, operational environments and intended submission scenario before deciding whether a redesign is necessary. The guidance also says the eventual transition will withdraw IG 9.3.A and D.O, while D.J is withdrawn on publication. These statements need to be read with their timing and exceptions, rather than treated as an immediate withdrawal of every earlier entropy configuration.
Boundary choices now have explicit consequences
D.U makes the cryptographic boundary a practical design and evidence question. An RBG2 or RBG3 construction used directly by a module must sit entirely within that module’s boundary, including its deterministic generator, entropy source, optional conditioning component and health tests. RBG1 is different: its randomness source is external, seeds the generator once through a physically secure channel, and is not available for reseeding afterward. D.U therefore expects RBG1 to be uncommon, requires a caveat about operator obligations, and limits that arrangement to overall security levels 1 or 2.
For chained RBGC constructions, the location of the root, non-root generators and randomness source determines which validation evidence and caveats apply. D.U’s case table distinguishes an entirely internal root from constructions that cross the module boundary. Certain external-component cases are likewise limited to overall levels 1 or 2; a case in which the entire root RBG sits outside the module without an internal generator is not permitted unless the module is bound or embedded under IG 1.A. Drawing the actual boundary and data path before choosing a certificate claim exposes those differences. A generic statement that a system “uses a validated RBG” leaves out the conditions the guidance tests.
Security Policy documentation follows the same distinction. Until WebCryptik supports RBG certificate references directly, D.U calls for a certificate table in section 2.8, plus a diagram showing which RBG components are internal, external or part of a bound module. It also requires descriptions of instantiation and reseeding. If the RBG or entropy source needs configuration, section 11.1 must capture that setup; section 11.2 must state any operator procedures needed to enforce SP 800-90C requirements that validation testing does not itself establish. Those are submission and operating-instruction details for the specific module design, not instructions for every agency to change an installed product.
Physical testing and manual procedures also changed
New IG 7.4.A addresses environmental testing for physical security levels 3 and 4. Level 3 permits environmental failure protection (EFP) or environmental failure testing (EFT); level 4 requires EFP. The guidance specifies separate temperature and voltage conditions, documentation of the chosen approach for each condition, and evidence of how the module responds beyond operating limits. For EFP, a module beyond a tested limit must shut down or immediately zeroize unprotected sensitive security parameters, with the zeroization demonstrated if that is the response. It also addresses where protection mechanisms sit relative to the boundary and calibration of measurement equipment. These are test and evidence requirements for relevant physical module submissions, not a new environmental test for software-only modules. The full conditions are in IG 7.4.A.
The November 20 Management Manual, version 2.8 introduces section 7.1.14, Minor Administrative Correction (EDIT). It allows a lab and vendor to correct nontechnical validation information such as a typo or inaccurate description without changing the module’s design, validated configuration, security claims, operational environment or algorithms. The lab must justify the correction and supply updated documentation where applicable. An approved EDIT updates the existing validation information; it does not create a new certificate, change validation status or require regression testing. The manual distinguishes it from VUP, which has a narrower vendor-information or Security Policy grammar scope. Technical changes still require an appropriate revalidation or full validation.
Version 2.8’s revision history also records changes to reimbursement timing, the revalidation scenario table, rules against module-type changes under UPDT, and some same-certificate entropy-source allowances. These details can affect a submission plan even when they do not change the cryptographic design. The manual is administrative guidance for CMVP participants; the implementation guidance supplies the technical resolutions. Neither document, by itself, changes the certificate status of a particular product.
What a validation team can check now
For a planned submission, the useful first step is to classify the work: RBG validation, module validation, an update, or a narrow administrative correction. The next is to trace the randomness source through the RBG and module boundaries, record the certificates and operational environments, and compare those facts with the applicable D.T and D.U cases. Teams pursuing a new module submission should account for the May 2028 direct-E-certificate transition early enough to validate an appropriate G certificate. Hardware designs claiming levels 3 or 4 should review 7.4.A against their test plan. The authoritative test remains the current CMVP implementation guidance and Management Manual, read for the exact architecture and submission scenario.
